home *** CD-ROM | disk | FTP | other *** search
/ Network Support Library / RoseWare - Network Support Library.iso / time / tim386.exe / TIM386.TXT < prev   
Text File  |  1993-09-17  |  2KB  |  60 lines

  1.  
  2.               NOVELL TECHNICAL INFORMATION DOCUMENT
  3.  
  4. TITLE:              NetWare v3.10 Synctime NLM
  5. DOCUMENT ID:        TID000399
  6. DOCUMENT REVISION:  A
  7. DATE:               01JUL93
  8. ALERT STATUS:       Yellow
  9. INFORMATION TYPE:   Symptom Solution
  10. README FOR:         TIM386.EXE
  11.  
  12. NOVELL PRODUCT and VERSION:
  13. NetWare Pre 3.11 and 2.2
  14.  
  15. ABSTRACT:
  16. Contained in this file is the program SYNCTIME.  SYNCTIME is a NetWare
  17. Loadable Module (NLM), which forces the server's date and time to be
  18. synchronized to the hardware's clock at specified intervals.  This NLM
  19. eliminates the gradual loss of time experienced by the server due to
  20. "missed" clock ticks while the server is in real mode. The program is only
  21. for NetWare v3.10.
  22. _________________________________________________________________
  23.  
  24. DISCLAIMER
  25. THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. 
  26. NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. 
  27. HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION
  28. ONLY.  NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS
  29. INFORMATION.
  30. _________________________________________________________________
  31.  
  32. Self-Extracting File Name:  TIM386.EXE
  33.  
  34. Files Included     Size     Date        Time
  35.  
  36.   TIM386.TXT          (This File)
  37. SYNCTIME.NLM       1391    2-11-91     12:07a
  38.  
  39.  
  40. This README file accompanies SYNCTIME.NLM for NetWare 386 v3.10.
  41.  
  42. SYNCTIME is a NetWare Loadable Module which forces the server's date/time
  43. to be synchronized to the hardware's clock at specified intervals.  This
  44. NLM eliminates the gradual loss of time experienced by the server due to
  45. "missed" clock ticks while the server is in real mode.
  46.  
  47. The syntax for SYNCTIME is as follows:
  48.  
  49.                     LOAD SYNCTIME [DELAY=time]
  50.  
  51. The DELAY parameter specifies the number of seconds between clock updates.
  52. This parameter is optional, with the default being 60 seconds. When
  53. unloading SYNCTIME, it may take some time to complete the unloading process
  54. (up to the amount of DELAY time specified).
  55.  
  56. SYNCTIME is designed to run on NetWare 386 v3.10a ONLY.  Any future
  57. revision of the Operating System will require a new version of SYNCTIME.